ENERGY EFFICIENT MICROCLIMATE STABILIZATION FOR SEALED ARCHIVAL STORAGE ENCLOSURES

Authors

  • A.Neftissov Astana IT University
  • A. Biloshchytskyi Kyiv National University of Construction and Architecture
  • I. Kazambayev Astana IT University
  • A. Medetkhan Astana IT University
  • L. Kirichenko Astana IT University

DOI:

https://doi.org/10.54309/IJICT.2026.27.3.022

Keywords:

preventive conservation, archival storage, microclimate control, thermoelectric cooling, humidity buffering, energy efficiency, air quality

Abstract

Preventive conservation of documentary collections requires stable local conditions, yet whole-room conditioning can be energy intensive. This study evaluates a sealed archival enclosure combining four Peltier modules, passive humidity buffering, environmental sensing, and dew-point-protected control. A 2.83 h laboratory campaign compared hybrid, active, and passive modes while ambient temperature increased from 16 to 32 °C. Hybrid and active modes maintained the internal temperature near 18.4 °C and achieved 100% compliance with the 18 ± 2 °C target band, whereas passive operation achieved about 41% thermal compliance. Relative humidity remained within 50 ± 5% in all modes. Active and hybrid operation consumed about 0.058 kWh, compared with 0.0055 kWh in passive mode. Conservative peak comparisons indicated at least 83.0% attenuation of PM2.5 and 79.8% attenuation of total volatile organic compounds. The results demonstrate the short-term feasibility of localized, energy-aware archival microclimate control.

Downloads

Download data is not yet available.

Author Biographies

  • A.Neftissov , Astana IT University

    PhD, Associate Professor, Vice-Rector for Science and Innovation, Kazakh National University of Sport; Researcher at the Scientific and Innovation Center “Industry 4.0”, Astana IT University,

  • A. Biloshchytskyi, Kyiv National University of Construction and Architecture

    Doctor of Technical Sciences, Professor, Vice-Rector for Science and Innovation, Astana IT University, Astana, Kazakhstan; Professor in the Department of Information Technology, Kyiv National University of Construction and Architecture, Kyiv, Ukraine

  • I. Kazambayev, Astana IT University

    Master of Technical Sciences, Director of the Scientific and Innovation Center “Industry 4.0

  • A. Medetkhan, Astana IT University

    Master of Technical Sciences, Junior Researcher at the Scientific and Innovation Center “Industry 4.0”

  • L. Kirichenko, Astana IT University

    Master of Technical Sciences, Researcher at the Scientific and Innovation Center “Industry 4.0”, Astana IT University, Astana, Kazakhstan Department of Science and Commercialization, Kazakh National University of Sport, Astana, Kazakhstan

Downloads

Published

2026-09-15

How to Cite

ENERGY EFFICIENT MICROCLIMATE STABILIZATION FOR SEALED ARCHIVAL STORAGE ENCLOSURES. (2026). INTERNATIONAL JOURNAL OF INFORMATION AND COMMUNICATION TECHNOLOGIES, 7(3), 405-420. https://doi.org/10.54309/IJICT.2026.27.3.022

Similar Articles

1-10 of 177

You may also start an advanced similarity search for this article.